top-UPS         

                                        UPS Backup emergency battery backup power! 

UPS Backup emergency battery backup power      

A UPS instantly switches your computer to emergency battery backup power
and allows you to work through brief power outages without data loss or
downtime. UPS units also give you the time to save files and shut down
your computer safely in the event of an extended power failure. This UPS
also provides surge protection and filtering.

  Key Features:           

  • Protection
    • Battery-protected and surge-only outlets - Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment
    • Power conditioning - Protects connected loads from surges, spikes, lightning, and other power disturbances.
    • Dataline Surge Protection - Provides protection of connected equipment from power surges on the data lines.
    • Safety-agency approved - Ensures product testing and approval to work safely with the connected loads and within the environment.
  • Convenience
    • Audible alarms - Provides notification of changing utility power and UPS conditions.
    • Automatic self-test - Ensures early detection of potential problems by periodic testing of UPS components.
    • Cold-start capable - Provides temporary battery power when the utility power is out.
    • Hot-swappable batteries - Ensures clean, uninterrupted power to protected equipment throughout battery replacement.
    • Resettable circuit breakers - Enables quick recovery from UPS overload events.
    • Transformer-block spaced outlets - Protect equipment with input transformer blocks without blocking access to other receptacles.
  • Manageability
    • USB connectivity - Provides management of the UPS via USB port.

 


Specifications Back to Top 
Output Output power capacity: 750 VA
Output power capacity: 450 watts
Max Configurable Power: 750 VA
Max Configurable Power: 450 watts
Nominal output voltage: 120V
Output Connections:
   (5) NEMA 5-15R (Battery Backup)
   (5) NEMA 5-15R (Surge Protection)
Input Nominal input voltage: 120V
Input frequency: 50/60 Hz +/- 3 Hz (auto sensing)
Input Connection Type: NEMA 5-15P
Cord Length: 6 feet ( 1.83 meters )
Input voltage range for main operations: 88 - 139 V
Batteries & Runtime Battery type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Replacement battery cartridge: RBC4
RBC™ Quantity: 1
Typical backup time at half load: 19.1 minutes (225 Watts)
Typical backup time at full load: 5.9 minutes (450 Watts)
Runtime Chart: Back-UPS ES
Communications & Management Interface port: USB
Control panel: LED status display with On Line : On Battery : Replace Battery and Building Wiring Fault
Audible alarm: Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering Surge energy rating: 365 Joules
Filtering: Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449
Dataline protection: RJ-45 Modem/Fax/DSL/ISDN/10-100 Base-T protection , Cable modem / Video protection
Physical Maximum height: 4.88 inches ( 124 mm )
Maximum width : 11.61 inches ( 295 mm )
Maximum depth: 8.46 inches ( 215 mm )
Net weight: 19.10 lbs. ( 8.68 kg )
Color: Charcoal
Environmental Operating Environment: 0 - 40 °C ( 32 - 104 °F )
Operating Relative Humidity: 5 - 95 %
Operating Elevation: 0-10000 feet ( 0-3000 meters )
Storage Temperature: -15 - 45 °C ( 5 - 113 °F )
Storage Relative Humidity: 5 - 95 %
Storage Elevation: 0-50000 feet ( 0-15000 meters )
Audible noise at 1 meter from surface of unit: 45 dBA
Online thermal dissipation: 47 BTU/hr
Conformance Approvals: cUL Listed , CSA , FCC Part 15 Class B , FCC Part 68 , NOM , UL 1778 , UL 497A , UL 497B , UL 498

Specifications subject to change without notice.

             

 

  Warranty Back to Top 

 

 

     Back to TOP Back to TOP: